Transformer Vacuum Annealing Furnace
Transformer Vacuum Annealing Furnace
Description:
This furnace is mainly for annealing different kind of wound CRGO cores for transformers, to release inner stress and decrease iron loss.
Advantages:
-This furnace is horizontal and rectangular type, equipped with front-load trolley, convenient for loading & unloading workpieces, avoiding trolley interfering heating elements;
- Heating elements located more reasonable; heating temperature inside is more equal; rectangular furnace decreases idle space, saves evacuating duration, decreases nitrogen consumption.
- Equipped with heating uniform-temperature fan, cut down relative processing time and increase productivity.
- Heating element is made from nickel chromium alloy, longer life
- Equipped with PID temperature control instruments, very good temperature uniform inside the furnace, good for annealing result.
- The whole annealing progress is control by PLC, full automatic; Equipped with industrial computer, progress and cycle curve can be displayed, process data can be saved or printed.
|wound core annealing furnace| wound core annealing furance| wound core annealing oven| wound core annealing ovean|
Specifications:
No. | Item | Data |
1 | Inside effective size (L x W x H) | 2200 x 1000 x 1100 |
2 | Max. load capacity | about 5T |
3 | Max. heating temperature | 950ºC |
4 | Working temperature | 780~820ºC |
5 | Heating power | 120kW |
6 | Temperature control method | PLC |
7 | Temperature control precision | ±2ºC |
8 | Temperature evenness inside | ±5ºC (in the later stage of temperature keeping) |
9 | Furnace surface temperature rise | 35ºC+ ambient temperature |
10 | Cooling fan motor power | 7.5kW |
11 | Ultimate vacuity | 20Pa |
12 | Working vacuity | 400Pa |
13 | Vacuuming speed | ≤30min (from atmosphere to vacuity 300~900Pa |
14 | Vacuum leakage speed | 50Pa/h |
15 | Cooling water consumption | 10~12t/h (water pressure 0.4MPa) |
|vacuum annealing oven|vacuum annealing oven| vacuum annealing oven| vacuum annealing oven| vacuum annealing